Continuous system / G(s) = N(s) / D(s)

Coefficients in descending powers (1 3 2) or an expression such as s(s+1)(s+2).

T in seconds. The sampling frequency is ωs = 2π/T.

Method
G(s) =1s³ + 3s² + 2s
Discrete system (Zero-order hold)
G(z) =0.001151z² + 0.003973z + 0.0008525z³ − 2.489z² + 2.038z − 0.5488
Poles of G(z)
0.67030.81871
Zeros of G(z)
−3.222−0.2299
DC gain G(1)
∞
largest |z|
1
Stability
G(z) is marginally stable: poles on the unit circle.
Difference equation

y[k] = 2.489·y[k−1] − 2.038·y[k−2] + 0.5488·y[k−3] + 0.001151·u[k−1] + 0.003973·u[k−2] + 0.0008525·u[k−3]

Sampling frequency ωs
31.42 rad/s
Nyquist frequency π/T
15.71 rad/s
Fastest pole |p|·T
0.4
Largest gap from y(kT)
0 (exact for a held step)
z-plane

The continuous system is not stable, so the plot shows the growing response over a short horizon.

Output y(t): Continuous y(t), Discrete y[k]

All three methods at this T

MethodG(z)PolesGap from y(kT)Stable
Zero-order hold(0.001151z² + 0.003973z + 0.0008525) / (z³ − 2.489z² + 2.038z − 0.5488)0.6703, 0.8187, 10 (exact for a held step)marginal
Tustin (bilinear)(0.0007576z³ + 0.002273z² + 0.002273z + 0.0007576) / (z³ − 2.485z² + 2.03z − 0.5455)0.6667, 0.8182, 10.05marginal
Matched pole–zero(0.001494z² + 0.002988z + 0.001494) / (z³ − 2.489z² + 2.038z − 0.5488)0.6703, 0.8187, 10.00499marginal

Same result in code

MATLAB
% G(s) = (1) / (s^3 + 3s^2 + 2s)
G = tf([1], [1 3 2 0]);
Ts = 0.2;
Gd = c2d(G, Ts, 'zoh')
p = pole(Gd), abs(p)   % stable when every |p| < 1
z = zero(Gd)
[b, a] = tfdata(Gd, 'v')   % y[k] = -a(2)y[k-1] - ... + b(1)u[k] + b(2)u[k-1] + ...
step(G, Gd); grid on   % continuous against discrete
Python (python-control)
import numpy as np
import control as ct

G = ct.tf([1], [1, 3, 2, 0])
Ts = 0.2
Gd = ct.sample_system(G, Ts, method='zoh')
print(Gd)
p = ct.poles(Gd); print(p, np.abs(p))  # stable when every |p| < 1
print(ct.zeros(Gd))
resp = ct.step_response(Gd)

MATLAB uses the Control System Toolbox; Python uses python-control 0.10 or later (pip install control).

WHAT IT COMPUTES

What this calculator computes

A pulse transfer function G(z) = Y(z)/U(z) that relates the samples y[k] = y(kT) to the computer's commands u[k], and the same relation written as a difference equation.

For the z-transform lecture's plant 1/(s + 1) at T = 0.2 s, the zero-order hold gives G(z) = 0.1813/(z − 0.8187): the pole is e^(−0.2) and the DC gain stays 1. Tustin turns the lecture's filter 10/(s + 10) at T = 0.05 s into 0.2(z + 1)/(z − 0.6).

READ THE RESULT

How to read the result

  • Poles inside the unit circle mean a stable G(z); a pole on the circle is marginal. The zero-order hold and matched methods put each continuous pole p at z = e^(pT); Tustin puts it at (1 + pT/2)/(1 − pT/2).
  • The difference equation is G(z) read with z⁻¹ as a one-sample delay: y[k] comes from earlier outputs and the current and earlier inputs. When G(z) is strictly proper only earlier inputs appear, so a controller has one sample to compute.
  • The step plot shows the continuous response as a curve and y[k] as dots. With the zero-order hold the dots sit exactly on the curve, because the hold makes the input exactly a step; the largest gap at the sampling instants is listed for every method.
METHOD

Method and conventions

  • Zero-order hold: G(s) is realized in state space, and one matrix exponential of [[A, B], [0, 0]]·T gives Φ = e^(AT) and Γ = ∫₀ᵀ e^(Aτ)dτ·B. Then G(z) = C(zI − Φ)⁻¹Γ + D, the way MATLAB c2d computes it.
  • Tustin substitutes s = (2/T)(z − 1)/(z + 1). With a prewarp frequency ω the factor 2/T becomes ω/tan(ωT/2), so G(z) on the unit circle equals G(jω) exactly at that frequency.
  • Matched pole–zero maps poles and finite zeros by z = e^(sT), sends all but one zero at infinity to z = −1 so that one sample of delay remains, and matches the DC gain (with integrators, the low-frequency gain). This is MATLAB's convention; textbooks often move the last zero to −1 as well, and python-control moves none, so its code adds them.
LIMITS

One input and one output, proper G(s) up to degree 12, and T from 1 µs to 1000 s. When T is short compared with the slowest pole, the poles crowd near z = 1 and the polynomial coefficients lose digits; MATLAB has the same limit. Time delay is not modeled.