EIGENROOMLAB WORKSHEET 14Cart-pole · State space
Control from estimated state
NameSectionDate
Goal
Compare control from an estimated state with full-state LQR under the same weights and nudge.
Setup
Lab eigenroom.com/lab?lesson=lqg · short link eigenroom.com/lqg
Open it on a phone or a computer; there is nothing to log in to or install. The link loads run A's settings:
- Initial angle
- 6°
- Controller type
- LQG
- Position cost
- 10
- Angle cost
- 100
- Force cost
- 1
- Process variance Q
- 0.00001
- Sensor variance R
- 0.001
- Sensor noise
- 0.3
- Disturbance events
- Nudge cart 1.2 N·s at 1.4 s
- Recording
- 8 s
- APreset, exactly as the link opens it.
- BChange only: Controller type → LQR.
Pin each run before you change a setting, so you can compare runs at the same replay time.
1. Predict
Does estimated-state feedback recover like full-state LQR after the same kick?
Write your prediction and a reason before you run anything.
2. Observe
Read each value in the lab and write it in the table.
| Quantity | Where to read it | A | B |
|---|---|---|---|
| Peak angle (°) | Measured response | ||
| Peak cart travel (m) | Measured response | ||
| Final cart position (m) | Measured response | ||
| Control effort (N·s) | Measured response |
3. Explain
With the same weights and the same nudge, which run travels further and uses more control effort? Why?
Both runs keep the pole up. Which property of full-state LQR does LQG not inherit, and what in this model breaks the optimality claim for both?
Extension (optional)
Set the sensor noise to 0 and run LQG again (run C). How close does it come to LQR?