EIGENROOMLAB WORKSHEET 05DC motor · PID tuning

Damping and noise

NameSectionDate

Goal

Measure what derivative action does to the controller's output when the speed measurement is noisy, and test whether it reduces overshoot in this loop.

Setup

Open it on a phone or a computer; there is nothing to log in to or install. The link loads run A's settings:

Target speed
120 rad/s
Loop
Closed loop
Controller type
PID
Proportional Kp
0.22
Integral Ki
0.6
Derivative Kd
0.012
Anti-windup
On
Load torque
0.04 N·m
Sensor noise
0.3
Controller period
20 ms
Disturbance events
None
Recording
12 s
  1. APreset, exactly as the link opens it.
  2. BChange only: Derivative Kd → 0.
  3. CChange only: Sensor noise → 0.

Pin each run before you change a setting, so you can compare runs at the same replay time.

1. Predict

Can D calm overshoot while the sensor signal is noisy?

Write your prediction and a reason before you run anything.

2. Observe

Read each value in the lab and write it in the table.

QuantityWhere to read itABC
Requested voltage spread, 10–12 s (max − min) (V)Control effort plot
Overshoot vs target (%)Measured response
Settling, ±2% of target (s)Measured response
Control effort (V·s)Measured response

3. Explain

  1. Compare runs A and B, both with sensor noise. What does D do to the requested voltage after the motor has settled?

  2. Did D reduce the overshoot here? Compare A with B, and look at run C, which has D but no noise.

Extension (optional)

Raise Kd to 0.03 with the noise on. What happens to the requested-voltage spread and to the overshoot?

Source: eigenroom.com/worksheets/motor/derivativeCite: EIGENROOM. (2026). Damping and noise [Lab worksheet]. Accessed YYYY-MM-DD. https://eigenroom.com/worksheets/motor/derivative