EIGENROOMLAB WORKSHEET 01DC motor · Feedback basics
Find the feedback loop
NameSectionDate
Goal
Read a feedback loop in numbers: how fast the motor reaches its target, how far it overshoots and how much voltage it needs to stay there.
Setup
Lab eigenroom.com/lab?lesson=feedback · short link eigenroom.com/feedback
Open it on a phone or a computer; there is nothing to log in to or install. The link loads run A's settings:
- Target speed
- 120 rad/s
- Loop
- Closed loop
- Controller type
- PID
- Proportional Kp
- 0.22
- Integral Ki
- 0.6
- Derivative Kd
- 0.008
- Anti-windup
- On
- Load torque
- 0.04 N·m
- Sensor noise
- 0
- Controller period
- 20 ms
- Disturbance events
- None
- Recording
- 12 s
- APreset, exactly as the link opens it.
- BChange only: Target speed → 80 rad/s.
Pin each run before you change a setting, so you can compare runs at the same replay time.
1. Predict
Where does the motor speed go after you change the target?
Write your prediction and a reason before you run anything.
2. Observe
Read each value in the lab and write it in the table.
| Quantity | Where to read it | A | B |
|---|---|---|---|
| Rise time, 10–90% of target (s) | Measured response | ||
| Overshoot vs target (%) | Measured response | ||
| Settling, ±2% of target (s) | Measured response | ||
| Final error (rad/s) | Measured response | ||
| Requested voltage at t = 0 s (V) | Readout at 0 s | ||
| Applied voltage at t = 12 s (V) | Readout at 12 s |
3. Explain
Both runs end with zero error, yet the applied voltage at 12 s differs. Why does run A need more voltage than run B to stay at its target?
If the loop were linear, the overshoot in percent would not depend on the target. Compare the two overshoots. What does the requested voltage at t = 0 s tell you about why they differ?
Extension (optional)
Lower the target until the request at t = 0 s stays within 12 V: try 50 rad/s, then 25 rad/s. Does the percentage overshoot now stay the same when you halve the target?