EIGENROOMLAB WORKSHEET 15DC motor · Design challenges

Tracking or disturbance rejection?

NameSectionDate

Goal

Show that tracking a target and rejecting a load are separate tests of the same loop.

Setup

Open it on a phone or a computer; there is nothing to log in to or install. The link loads run A's settings:

Target speed
120 rad/s
Loop
Closed loop
Controller type
PID
Proportional Kp
0.22
Integral Ki
0
Derivative Kd
0
Anti-windup
On
Load torque
0 N·m
Sensor noise
0
Controller period
20 ms
Disturbance events
None
Recording
12 s
  1. APreset, exactly as the link opens it.
  2. BChange only: Disturbance events → Step load 0.06 N·m from 4 s. Pin run A, then add a Step load at 4 s from the disturbance buttons and set its magnitude as listed.

Pin each run before you change a setting, so you can compare runs at the same replay time.

1. Predict

Can one good target response prove that a motor rejects a shaft load?

Write your prediction and a reason before you run anything.

2. Observe

Read each value in the lab and write it in the table.

QuantityWhere to read itAB
Speed at t = 3.9 s (rad/s)Readout at 3.9 s
Speed at t = 12 s (rad/s)Readout at 12 s
Applied voltage at t = 12 s (V)Readout at 12 s
Final error (rad/s)Measured response

3. Explain

  1. Runs A and B are identical until 4 s. How much speed does the load cost, and how much voltage does the P controller add?

  2. Which change to the controller would bring the speed back after the load, and what would still limit it?

Extension (optional)

Add Ki = 0.6 and repeat with the load (run C) and without it (run D). Compare the settling time of the target step alone with the settling time after the load.

Source: eigenroom.com/worksheets/motor/tracking-rejectionCite: EIGENROOM. (2026). Tracking or disturbance rejection? [Lab worksheet]. Accessed YYYY-MM-DD. https://eigenroom.com/worksheets/motor/tracking-rejection