EIGENROOMLAB WORKSHEET 26Mass–spring–damper
Drive near resonance
NameSectionDate
Goal
Measure the steady amplitude of a forced mass–spring–damper below, near and above resonance.
Setup
Lab eigenroom.com/lab/mechanics?lesson=resonance · short link eigenroom.com/resonance
Open it on a phone or a computer; there is nothing to log in to or install. The link loads run A's settings:
- Mass m
- 1 kg
- Stiffness k
- 16 N/m
- Damping c
- 1.6 N·s/m
- Input type
- Sine force
- Force / amplitude
- 1 N
- Angular frequency
- 1 rad/s
- Initial displacement
- 0 m
- Initial velocity
- 0 m/s
- Duration
- 20 s
- APreset, exactly as the link opens it.
- BChange only: Angular frequency → 3.84 rad/s.
- CChange only: Angular frequency → 8 rad/s.
Pin each run before you change a setting, so you can compare runs at the same replay time.
1. Predict
A 1 N sine force moves this mass. Does a faster input always produce more displacement?
Write your prediction and a reason before you run anything.
2. Observe
Read each value in the lab and write it in the table.
| Quantity | Where to read it | A | B | C |
|---|---|---|---|---|
| Sinusoidal particular-response amplitude (m) | Settings panel | |||
| Largest |x|, 15–20 s (m) | Plot, with the replay cursor | |||
| Peak absolute displacement (m) | Prediction check measures |
3. Explain
Does a faster input always produce more displacement?
In run C the largest displacement over the whole recording is larger than the steady amplitude. Where does the extra motion come from?
Extension (optional)
Set c = 0 and drive at 4 rad/s. What does the settings panel report, and what does the trace do?