EIGENROOMLAB WORKSHEET 26Mass–spring–damper

Drive near resonance

NameSectionDate

Goal

Measure the steady amplitude of a forced mass–spring–damper below, near and above resonance.

Setup

Open it on a phone or a computer; there is nothing to log in to or install. The link loads run A's settings:

Mass m
1 kg
Stiffness k
16 N/m
Damping c
1.6 N·s/m
Input type
Sine force
Force / amplitude
1 N
Angular frequency
1 rad/s
Initial displacement
0 m
Initial velocity
0 m/s
Duration
20 s
  1. APreset, exactly as the link opens it.
  2. BChange only: Angular frequency → 3.84 rad/s.
  3. CChange only: Angular frequency → 8 rad/s.

Pin each run before you change a setting, so you can compare runs at the same replay time.

1. Predict

A 1 N sine force moves this mass. Does a faster input always produce more displacement?

Write your prediction and a reason before you run anything.

2. Observe

Read each value in the lab and write it in the table.

QuantityWhere to read itABC
Sinusoidal particular-response amplitude (m)Settings panel
Largest |x|, 15–20 s (m)Plot, with the replay cursor
Peak absolute displacement (m)Prediction check measures

3. Explain

  1. Does a faster input always produce more displacement?

  2. In run C the largest displacement over the whole recording is larger than the steady amplitude. Where does the extra motion come from?

Extension (optional)

Set c = 0 and drive at 4 rad/s. What does the settings panel report, and what does the trace do?

Source: eigenroom.com/worksheets/mechanics/resonanceCite: EIGENROOM. (2026). Drive near resonance [Lab worksheet]. Accessed YYYY-MM-DD. https://eigenroom.com/worksheets/mechanics/resonance