EIGENROOMLAB WORKSHEET 22DC motor · Dead time and limits
Tuning against dead time
NameSectionDate
Goal
Answer the experiment's question with numbers read from the lab: On a motor with 200 ms of dead time, will the Ziegler–Nichols PI gains or half of them settle sooner?
Setup
Lab eigenroom.com/lab?lesson=detune-for-delay · short link eigenroom.com/detune-for-delay
Open it on a phone or a computer; there is nothing to log in to or install. The link loads run A's settings:
- Target speed
- 30 rad/s
- Loop
- Closed loop
- Controller type
- PID
- Proportional Kp
- 0.335
- Integral Ki
- 0.41
- Derivative Kd
- 0
- Anti-windup
- On
- Load torque
- 0 N·m
- Sensor noise
- 0
- Controller period
- 20 ms
- Disturbance events
- None
- Recording
- 12 s
- APreset, exactly as the link opens it.
- BColumn B: write down the one setting you changed.
Pin each run before you change a setting, so you can compare runs at the same replay time.
1. Predict
On a motor with 200 ms of dead time, will the Ziegler–Nichols PI gains or half of them settle sooner?
Write your prediction and a reason before you run anything.
2. Observe
Read each value in the lab and write it in the table.
| Quantity | Where to read it | A | B your change |
|---|---|---|---|
| Rise time, 10–90% of target (s) | Measured response | ||
| Overshoot vs target (%) | Measured response | ||
| Settling, ±2% of target (s) | Measured response | ||
| Final error (rad/s) | Measured response | ||
| Control effort (V·s) | Measured response |
3. Explain
Follow the lab's instruction: “Pin the Z–N run, then set P to 0.17 and I to 0.21, about half of each.” Record your changed run in column B. Which quantity changed the most, and in which direction?
Explain the change you measured. What you were asked to watch: “The preset is the Z–N PI suggestion from the reaction curve, Kp 0.336 and Ki 0.412, rounded to the sliders as 0.335 and 0.41. Compare overshoot, rise and settling with the halved gains, and the phase margin in the frequency workbench.”
Extension (optional)
Repeat the change with two more values of the same setting and sketch the measured quantity against the setting. Is the relationship linear?