EIGENROOMLAB WORKSHEET 07DC motor · PID tuning
Push back against a load
NameSectionDate
Goal
Measure how far a short load pulse pushes the speed and how the feedback voltage answers it.
Setup
Lab eigenroom.com/lab?lesson=disturbance · short link eigenroom.com/disturbance
Open it on a phone or a computer; there is nothing to log in to or install. The link loads run A's settings:
- Target speed
- 120 rad/s
- Loop
- Closed loop
- Controller type
- PID
- Proportional Kp
- 0.22
- Integral Ki
- 0.6
- Derivative Kd
- 0.008
- Anti-windup
- On
- Load torque
- 0.04 N·m
- Sensor noise
- 0
- Controller period
- 20 ms
- Disturbance events
- None
- Recording
- 12 s
- APreset, exactly as the link opens it.
- BChange only: Disturbance events → Tap load 0.06 N·m at 4 s for 0.25 s. Replay to 4 s and press Tap load, then check that the event list matches this run's settings.
Pin each run before you change a setting, so you can compare runs at the same replay time.
1. Predict
How does the loop recover when the shaft load increases?
Write your prediction and a reason before you run anything.
2. Observe
Read each value in the lab and write it in the table.
| Quantity | Where to read it | A | B |
|---|---|---|---|
| Lowest speed, 4–6 s (rad/s) | Plot, with the replay cursor | ||
| Highest applied voltage, 4–6 s (V) | Control effort plot | ||
| Settling, ±2% of target (s) | Measured response | ||
| Final error (rad/s) | Measured response |
3. Explain
How far does the speed fall during the tap, and what does the applied voltage do?
The target is the same in both runs. Why does the settling time change?
Extension (optional)
Replace the tap with a Step load of the same size at 4 s (run C). Does the speed return to the target?