EIGENROOMLAB WORKSHEET 08ANSWER KEY · FOR INSTRUCTORSDC motor · Lead and lag

Shape phase with lead

Goal

Relate a lead compensator's zero and pole to phase margin, speed and steady error.

Setup

Open it on a phone or a computer; there is nothing to log in to or install. The link loads run A's settings:

Target speed
120 rad/s
Loop
Closed loop
Controller type
Lead compensator
Controller gain
2
Zero frequency
4 rad/s
Pole frequency
8 rad/s
Load torque
0.04 N·m
Sensor noise
0
Controller period
20 ms
Disturbance events
None
Recording
12 s
  1. APreset, exactly as the link opens it.
  2. BChange only: Zero frequency → 6 rad/s.
  3. CChange only: Zero frequency → 2 rad/s. (ext.)

1. Predict

Can a zero before a pole quicken the response without an integrator?

What happens

A lead network adds positive phase over a band. It can improve the speed–robustness tradeoff but its finite DC gain does not guarantee zero steady error.

2. Observe

QuantityWhere to read itABC ext.
Phase margin (°)Frequency workbench48.7°42.1°54.9°
Gain margin (dB)Frequency workbench14.3 dB13.6 dB14.9 dB
Rise time, 10–90% of target (s)Measured response1.52 s1.34 s—
Final error (rad/s)Measured response9.35 rad/s6.37 rad/s17.54 rad/s

Values computed by DC motor and cart-pole engine 1.5.0 at the settings above. A replay readout can differ in the last digit if the slider is not exactly at the stated time; values read from a plot are approximate.

3. Explain

  1. Moving the zero toward the pole shrinks the phase lead. What happens to the phase margin and to the rise time?

    The phase margin falls from 48.7° to 42.1° while the rise time shortens from 1.52 s to 1.34 s. Less phase lead leaves less margin; the loop also gets faster because the compensator's low-frequency gain rose.

  2. Neither run settles inside ±2% of the target. Why can't a lead compensator remove the steady error on its own?

    Its gain at zero frequency, gain × zero / pole, is finite, so like a P controller it needs an error to hold the voltage: 9.35 rad/s for run A and 6.37 rad/s for run B. Moving the zero raised that gain and shrank the error; only an integrator makes it zero.

Extension (optional)

Move the zero to 2 rad/s instead. Predict the phase margin and the final error before you look.

More phase lead and a lower low-frequency gain: the phase margin rises to 54.9° and the final error grows to 17.54 rad/s.

Source: eigenroom.com/worksheets/motor/lead/answersCite: EIGENROOM. (2026). Shape phase with lead [Lab worksheet]. Accessed YYYY-MM-DD. https://eigenroom.com/worksheets/motor/lead