EIGENROOMLAB WORKSHEET 32ANSWER KEY · FOR INSTRUCTORSState feedback & observer

Recover a hidden velocity

Goal

Measure how quickly a Luenberger observer corrects a wrong initial estimate, and what a faster observer costs.

Setup

Open it on a phone or a computer; there is nothing to log in to or install. The link loads run A's settings:

Controller ωn
2 rad/s
Controller damping ζ
0.7
Observer speed ratio
1
Feedback state
Observer estimate
Target position
0.2 m
Initial position
0 m
Initial estimate error
0.3 m
Position noise amplitude
0 m
Force limit
10 N
  1. APreset, exactly as the link opens it.
  2. BChange only: Observer speed ratio → 3.
  3. CChange only: Feedback state → True state.
  4. DChange only: Initial estimate error → 0 m. (ext.)

1. Predict

Only position is measured. Can the observer correct an initially wrong position estimate and infer velocity?

What happens

The innovation y−C x̂ corrects a model prediction. L places the eigenvalues of A−LC; faster error dynamics remove this initial mismatch sooner but can produce a transient peak in estimated velocity. The observer receives the applied, clipped force, not an unavailable requested force. Separation of controller and observer poles assumes a linear, unsaturated exact model.

2. Observe

QuantityWhere to read itABCD ext.
Position estimation error at t = 0.2 s (m)Readout at 0.2 s-0.17708 m-0.0022004 m-0.17708 m0 m
Position estimation error at t = 0.5 s (m)Readout at 0.5 s-0.060512 m0.035632 m-0.060512 m0 m
Peak |estimated velocity|, 0–1 s (m/s)Plot, with the replay cursor0.109 m/s0.4125 m/s0.05149 m/s0.1834 m/s
Peak |applied force|, 0–1 s (N)Plot, with the replay cursor0.8 N1.625 N0.8 N0.8 N
Position at t = 1 s (m)Readout at 1 s0.18397 m0.24809 m0.14514 m0.14514 m

Values computed by State-feedback, tank and RLC engine 1.0.0 at the settings above. A replay readout can differ in the last digit if the slider is not exactly at the stated time; values read from a plot are approximate.

3. Explain

  1. How much faster does the estimation error shrink in run B?

    At 0.2 s the error is -0.0022004 m in run B against -0.17708 m in run A: the observer poles are three times faster, so the initial mismatch decays sooner.

  2. What does the faster observer cost?

    In the first second its estimated velocity peaks at 0.4125 m/s, against 0.109 m/s, and the applied force peaks at 1.625 N instead of 0.8 N: correcting the initial error quickly produces a transient that the controller acts on.

  3. Run C feeds back the true state. Why is its estimation error the same as run A's?

    The estimation error obeys e′ = (A − LC)e, which does not depend on the control input when the observer receives the applied force; at 0.5 s both show -0.060512 m. The control differs: the position at 1 s is 0.14514 m against 0.18397 m.

Extension (optional)

Set the initial estimate error to 0 with run A's other settings (run D). Does observer feedback still differ from true-state feedback?

No: with a correct initial estimate and no noise the estimate equals the true state, and the position at 1 s is 0.14514 m, as in run C.

Source: eigenroom.com/worksheets/state-feedback/observer-recovery/answersCite: EIGENROOM. (2026). Recover a hidden velocity [Lab worksheet]. Accessed YYYY-MM-DD. https://eigenroom.com/worksheets/state-feedback/observer-recovery