EIGENROOMLAB WORKSHEET 31State feedback & observer
Move the closed-loop poles
NameSectionDate
Goal
Place the closed-loop poles of a mass–spring–damper and measure the force a faster design asks for.
Setup
Lab eigenroom.com/lab/state-feedback?lesson=place-poles · short link eigenroom.com/place-poles
Open it on a phone or a computer; there is nothing to log in to or install. The link loads run A's settings:
- Controller ωn
- 2 rad/s
- Controller damping ζ
- 0.7
- Observer speed ratio
- 2
- Feedback state
- True state
- Target position
- 0.2 m
- Initial position
- 0 m
- Initial estimate error
- 0.3 m
- Position noise amplitude
- 0 m
- Force limit
- 10 N
- APreset, exactly as the link opens it.
- BChange only: Controller ωn → 4 rad/s.
- CChange only: Controller ωn → 6 rad/s.
Pin each run before you change a setting, so you can compare runs at the same replay time.
1. Predict
Does doubling the desired natural frequency improve speed without any cost?
Write your prediction and a reason before you run anything.
2. Observe
Read each value in the lab and write it in the table.
| Quantity | Where to read it | A | B | C |
|---|---|---|---|---|
| Requested force at t = 0 s (N) | Readout at 0 s | |||
| Position at t = 0.5 s (m) | Readout at 0.5 s | |||
| Position at t = 1 s (m) | Readout at 1 s | |||
| Clipped command time (s) | Results below the plots |
3. Explain
How does the force requested at t = 0 s grow with ωn, and why?
None of these runs reaches the force limit. What happens to the pole-placement design once the request exceeds it?
Extension (optional)
Keep ωn = 6 rad/s and raise the target position to 0.5 m (run D). How long is the command clipped?