EIGENROOMLAB WORKSHEET 34ANSWER KEY · FOR INSTRUCTORSWater tank

A tangent is a local model

Goal

Test where a tangent (linearized) model of a draining tank stops predicting the real level.

Setup

Open it on a phone or a computer; there is nothing to log in to or install. The link loads run A's settings:

Tank area A
0.1 m²
Outlet coefficient c
0.003 m⁵ᐟ²/s
Linearization height h₀
0.5 m
Initial height
0.5 m
Target height
0.8 m
Pump control
Manual step about q₀
Flow step Δq
0.0002 m³/s
Pump limit
0.005 m³/s
Kp
0.004 m²/s
Ki
0.00003 m²/s²
Anti-windup
On
Extra drain from 30 s
0 m³/s
  1. APreset, exactly as the link opens it.
  2. BChange only: Flow step Δq → 0.0015 m³/s.
  3. CChange only: Flow step Δq → -0.0015 m³/s. (ext.)

1. Predict

Will a linear model around h₀ = 0.5 m match both a small and a large flow change?

What happens

Outflow is c√h. The tangent slope at h₀ is c/(2√h₀), giving a local first-order model. The linear trace uses the same actual pump signal; it is not a separately controlled plant. Large excursions make the tangent less representative. The run stops at an empty tank or the 2 m rim.

2. Observe

QuantityWhere to read itABC ext.
Nonlinear height at t = 30 s (m)Readout at 30 s0.54459 m0.84251 m0.18243 m
Nonlinear height at t = 120 s (m)Readout at 120 s0.58945 m1.2716 m0.043282 m
Linear prediction at t = 120 s (m)Readout at 120 s0.58689 m1.1517 m-0.15165 m
Nonlinear − linear height at t = 120 s (m)Readout at 120 s0.002559 m0.12 m0.1949 m

Values computed by State-feedback, tank and RLC engine 1.0.0 at the settings above. A replay readout can differ in the last digit if the slider is not exactly at the stated time; values read from a plot are approximate.

3. Explain

  1. How well does the tangent model predict each run at 120 s?

    Run A: nonlinear 0.58945 m, linear 0.58689 m, a gap of 0.002559 m. Run B: 1.2716 m and 1.1517 m, a gap of 0.12 m. The small step stays near h₀, where the tangent fits √h; the large one climbs far along the curve.

  2. Which way is the linear model wrong in run B, and why?

    It predicts too low a level (1.1517 m against 1.2716 m). The tangent to the concave outflow curve c√h lies above it, so away from h₀ the linear model overestimates the outflow and expects the tank to settle lower.

Extension (optional)

Try Δq = -0.0015 m³/s, a large decrease (run C). Which way is the linear model wrong now?

Still too low: at 120 s the tank is at 0.043282 m while the linear model says -0.15165 m, a level below an empty tank. The tangent lies above the outflow curve on both sides of h₀, so it overestimates the outflow whichever way the level moves, and nothing stops a linear model from predicting impossible values.

Source: eigenroom.com/worksheets/tank/local-tank-model/answersCite: EIGENROOM. (2026). A tangent is a local model [Lab worksheet]. Accessed YYYY-MM-DD. https://eigenroom.com/worksheets/tank/local-tank-model