EIGENROOMLAB WORKSHEET 35Water tank

The same tank has different time scales

NameSectionDate

Goal

Compare the same tank's local time constant and gain at two operating heights.

Setup

Open it on a phone or a computer; there is nothing to log in to or install. The link loads run A's settings:

Tank area A
0.1 m²
Outlet coefficient c
0.003 m⁵ᐟ²/s
Linearization height h₀
0.5 m
Initial height
0.5 m
Target height
0.8 m
Pump control
Manual step about q₀
Flow step Δq
0.0002 m³/s
Pump limit
0.005 m³/s
Kp
0.004 m²/s
Ki
0.00003 m²/s²
Anti-windup
On
Extra drain from 30 s
0 m³/s
  1. APreset, exactly as the link opens it.
  2. BChange only: Linearization height h₀ → 1 m, Initial height → 1 m.

Pin each run before you change a setting, so you can compare runs at the same replay time.

1. Predict

Does the water level return on the same time scale at low and high operating heights?

Write your prediction and a reason before you run anything.

2. Observe

Read each value in the lab and write it in the table.

QuantityWhere to read itAB
Local time constant τ₀ = 2A√h₀/c (s)Settings panel
Height change from the start at t = 30 s (m)Readout at 30 s
Height change from the start at t = 120 s (m)Readout at 120 s

3. Explain

  1. For the same Δq, which run's level has risen more by 120 s?

  2. Compare the local time constants, then the rise at 30 s. Why are the early rises so similar?

Extension (optional)

Set the operating and initial height to 1.5 m (run C). Predict τ₀ and the rise at 120 s.

Source: eigenroom.com/worksheets/tank/tank-operating-pointCite: EIGENROOM. (2026). The same tank has different time scales [Lab worksheet]. Accessed YYYY-MM-DD. https://eigenroom.com/worksheets/tank/tank-operating-point