MODEL / EXPERIMENT / EXPLANATION

Place poles. Estimate what you cannot see.

A position-sensed mass–spring–damper with designed state feedback and a Luenberger observer. Compare true and estimated states, noise and actuator limits.

Move the closed-loop poles

Does doubling the desired natural frequency improve speed without any cost?

Pin ωn = 2. Change only ωn to 4, then 6 rad/s. Compare position and requested/applied force. Keep damping and the initial state fixed.

Printable worksheet →

Termspole placementstate feedbackAckermann's formulacontrollability

PHYSICAL STATE / REPLAYCalculating…
— s
View traces ↓

Synchronized signals

Loading plot…
Position— m
Estimated position— m
Target— m

Select a trace or use the replay slider. The first current signal is cyan; secondary signals and numbered pinned runs are dashed. Every setting change recalculates from the initial state.

CHECK YOUR PREDICTION

Did the result match your prediction?

Choose a measurable prediction before changing a setting. Record the current result, change one condition, then check. This compares complete recordings, not the replay cursor.

Waiting for a complete, valid result. A stopped run or unavailable metric cannot be judged; choose another measure if needed.

Prediction and baseline stay in memory for this page only. Use Start a new prediction to choose a new baseline.

Compare one change 0/3

Keep initial state, inputs and seed matched when comparing controllers. Pinned traces retain their original settings and stop time.

Observed result

Recorded duration: 0 s · Clipped command time: — s

Final target error: — m

These observations describe a finite run, not a general stability or robustness guarantee.

Equations, assumptions and method

x′ = Ax + Bu; ureq = −Kx̂ + Nr; x̂′ = Ax̂ + Buapplied + L(y − Cx̂)

m = 1 kg, k = 4 N/m, c = 0.8 N·s/m; x = [position, velocity], y = position + noise. Continuous controller and observer, RK4 at 1 ms, recorded every 20 ms. Observer damping is 0.8; its natural frequency is the chosen ratio times controller ωn. Uniform seeded noise is held for 20 ms. Saturation is included; delays, model mismatch and process noise are not. This is not a sampled digital implementation or a Kalman filter.

Next experiment 02Recover a hidden velocity

Read the related Field Journal →

ωnController ωn2.0 rad/s